Problem 1:Pump fails to operate

Q1. Power failure
A1. Check the voltage. Contact power supplier for solution


Q2. Defective cable
A2. Replace power cable

Q3. Impeller jammed or clogged
A3. Clean the impeller

Q4. The motor protector tripped
A4. Make sure liquid temperature is below 40°C pump and is completely submerged

Q5. Motor burn-out
A5. Rewind or replace the motor

Q6. Water gets into motor after mechanical seal wear
A6. Replace the mechanical seal & oil seal

Q7. Float switch defective
A7. Replace a float switch

Q8. Impeller rusted
A8. Remove rust

Q9. Faulty Control Panel
A9. Repair or replace

Problem 2:Does not pump. Inadequate volume / Low value of aeration in J Series Pump

Q1. Motor rotation reversed
A1. Reverse two of three leads on a three phase motor

Q2. Impeller worn or cavitation
A2. Replace Impeller

Q3. Strainer block
A3. Remove and clean the foreign objects

Q4. Impeller block
A4. Remove and clean the foreign objects

Q5. Valves and pipe leakage or plugged
A5. Remove plugged objects or replace

Q6. Excessive water head
A6. Consult the distributor

Q7. Air suction due to low water level
A7. Raise the water lever or adjust the float switch higher

Q8. Clogged aeration chamber (J series)
A8. Remove the foreign objects

Q9. Worn nozzle (J series)
A9. Replace with a new nozzle

Q10. Water level too high (J series)
A10. Adjust the Level Switch lower

Problem 3:Over Current

Q1. Abnormal voltage
A1. Check the power, and make sure it corresponds to the nameplate

Q2. Incorrect rotation
A2. Reverse two of three leads on a three phase motor

Q3. High viscosity liquid
A3. More liquid needs to be added to the pump fluid to decrease its viscosity(contact the distributor)

Q4. Foreign matter clogging pump or impeller
A4. Remove the foreign objects

Q5. Worn Shaft
A5. Repair and replace


Problem 4: Stops during operationPump

Q1. Foreign matter clogging pump or impeller
A1. Remove the foreign objects

Q2. Abnormal voltage
A2. Check the power, and make sure it corresponds to the nameplate

Q3. The motor protector tripped
A3. Make sure liquid temperature is below 40°C and pump is completely submerged

Problem 5:Electric Leakage Circuit Breaker Activated

Q1. Power Cable damaged
A1. Replace new power cable

Q2. Wet cable terminal
A2. Re-connect wires using waterproof tape after drying

Q3. Water ingress caused by worn mechanical seal
A3. Replace new Mechanical seals and oil seal

Q4. Motor burn out
A4. Repair or replace new motor
1. การแก้ไขปัญหา – ปั๊มแบบปล่อยน้ำด้านข้าง   